• Automatic stripping machine can not start running or running stop if this happens, first we do not worry, first check whether the current input (220V) and 6KG pressure, and then check the set total number without arriving, wireless material or a running part stuck, finally check the terminal machine with no signal connection or power connection. The following is a brief introduction to several common couples and processing methods.

  • 1, the machine can not start running or running in the stop 
    If this happens, first we do not worry, first check whether the current input (220V) and 6KG pressure, and then check the set total number without arriving, wireless material or a running part stuck, finally check the terminal machine there is no signal connection or power supply connected to the terminal machine pressure guide a.

  • 2, a terminal exposed wire uneven pressure
    To produce this kind of phenomenon, we should step by step to. First check the gun type arm swing catheter and wire attached, then check the terminal machine blade is relatively straight and the swing arm catheter, then check the terminal machine auxiliary pressing block is loosened, the final check between a terminal machine and the automaton distance has no change. After this series of checks, you can find the cause of the fault. No signal connection or power supply connection and the terminal machine is not pressed.

  • 3, without thread stripping
    Check the thread cutting depth, such as too shallow, to increase the line size; in line two gap is too large, small adjustment. Feed wheel knob pressure is not enough, need to press the head to strip the data is too small, need to increase.

  • 4, the end of the line is not open
    Check the cutting depth of the end of the line, such as too shallow, need to increase the diameter of the wire or function key F3 wrapped tail depth increase the information. Outlet up and down the two rounds of clearance is too large, the adjustment is small, outlet wheel spin twist pressure is not enough, need to press. Tail stripped data is too small, need to increase.

  • 5, the electronic wire cut off length is not consistent
    This kind of breakdown, because of the three kinds of circumstances. The first is the automatic stripping machine and wire feeding wheel pressure too tight or too loose, if it is because of this phenomenon, so we only need to roll between the line wheel and the wire gap adjustment two pieces of fine not compressed and loose slip, can solve this fault; the second is the straightener tight or loose, if it is because of this problem, so our approach should be adjusted from the straightening device can play straightening and can successfully sent the principle to solve; finally is tangent to the blade wear or knife edge, for this phenomenon, we only need to replace the new cutter can.

  • 6, wire surface pressure is too heavy
    First judge the pressure pattern is the line or the outlet wheel pressure caused by. If it is in the wire wheel, the gap between the wire and the wire will be changed greatly. If the outlet wheel, the outlet wheel adjustment gap larger. If the outlet wheel, the outlet wheel adjustment gap larger. The catheter is too far away from the edge of the distance, need to adjust the near.